Technical

Technical

  • Meaning of test terms in circuit breaker dynamic characteristic tester

    Meaning of test terms in circuit breaker dynamic characteristic tester

    During the use of the circuit breaker dynamic characteristic tester, electric workers will use some professional terms to describe the test results or test process. So, what does the test term mean when testing circuit breakers? The following article introduces it to you.                        ...
    Read more
  • What are the components of the insulating boots (gloves) hipot test set?

    What are the components of the insulating boots (gloves) hipot test set?

    Insulating boots and gloves withstand voltage test device is one of the commonly used safety testing equipment in electrical engineering. It is mainly used to measure the withstand voltage performance of insulating devices such as insulating gloves and insulating boots to ensure the safety of ele...
    Read more
  • Why test the dielectric strength of insulating oil?

    Why test the dielectric strength of insulating oil?

    The main reason for testing the dielectric strength of insulating oil is that the dielectric strength of insulating oil is an important index reflecting the quality of insulating oil, and this index can directly reflect the withstand voltage capability of insulating oil. The dielectric strength o...
    Read more
  • What are the requirements for DC resistance tester to detect power transformers

    What are the requirements for DC resistance tester to detect power transformers

    For power transformers with a voltage level of 10KV and below, the detection requirements in the winding DC resistance test item are: the transformer is 1.6MVA and below, and the requirements for phase-to-phase difference regulations: it should not be greater than 4% of the average value of the t...
    Read more
  • Common problems and solutions in transformer high voltage test

    Common problems and solutions in transformer high voltage test

    In the high-voltage test of transformers, many key points should be paid attention to, and the test conditions and test methods must be accurately grasped. The faults that occur in the high voltage test of the transformer should be screened one by one, and the faults should be properly handled. E...
    Read more
  • Common troubleshooting methods of Capacitance and Tan Delta tester

    Common troubleshooting methods of Capacitance and Tan Delta tester

    It is inevitable that the test data of the high-voltage dielectric loss tester will be obviously unreasonable during use. Once this positive problem occurs, the reason can be found from the following aspects: 1. Poor contact of the hook When using a hook to connect the test object for on-site mea...
    Read more
  • Electrical safety common sense training

    Electrical equipment will not endanger human health and surrounding equipment during normal operation and under expected abnormal conditions. When electrical equipment fails unexpectedly, it should be able to cut off the power supply and limit the accident within the allowable range. If electrica...
    Read more
  • Measuring principle of transformer on-line monitoring

    Measuring principle of transformer on-line monitoring

    One of the effective methods for on-line detection of transformer insulation is to monitor the parameters of partial discharge electric pulses. In the normal operation of the transformer, the partial discharge is small. In recent years, the partial discharge of the transformers above 110kV produc...
    Read more
  • The use range and precautions of Insulating Hipot Gloves (boots) Test Set

    The use range and precautions of Insulating Hipot Gloves (boots) Test Set

    The new standard stipulates that electrically insulating shoes shall be used as safety aids for electrical work. As an occupational safety manager, you should clearly understand this. Usually, managers with insufficient electrical knowledge will mistakenly think that 6kV insulated leather shoes o...
    Read more
  • Precautions for Series Resonance Test System

    Precautions for Series Resonance Test System

    Precautions for Series Resonance Test Syetem 1. During the test, the test phase is connected to the high-voltage source, and the high-voltage lead wire needs to use a special halo-free lead wire, and the non-test phase is grounded with the GIS shell; 2. The test must ensure that the SF6 gas in ea...
    Read more
  • How to effectively prevent overvoltage problems during substation operation

    How to effectively prevent overvoltage problems during substation operation

    In the process of operating the no-load transformer, there will be an unavoidable physical phenomenon, that is, cut-off. The problem of operating overvoltage due to the cut-off of the circuit breaker can be prevented by taking the following measures: 1. Improve the iron core Improving the iron co...
    Read more
  • How to measure the dielectric loss of transformer

    How to measure the dielectric loss of transformer

    First of all, we can understand that the dielectric loss is that the dielectric is under the action of an electric field. Because of the internal heating, it will convert electrical energy into heat energy and consume it. This part of the consumed energy is called dielectric loss. Dielectric loss...
    Read more

Send your message to us:

Write your message here and send it to us