GDCR9300 High Precision Wireless Clamp Multimeter for Electrical Testing

GDCR9300 High Precision Wireless Clamp Multimeter for Electrical Testing

Brief Description:

GDCR9300 Wireless H/L Voltage Hook Type Current Meter break through the traditional structure, specially designed and manufactured for measuring high voltage current, the unique hook type opening mouth structure realizes the unimpeded measurement, and very convenient for field test. The meter is composed of special large-caliber hook type current meter with high voltage insulation rod, equipped with wireless receiver, which can receive the measured data within 100 meters straight line distance, current range: AC 0.00A-9999A. In low voltage lines below 600V, the line current can be measured directly by hook meter without insulation rod.


Product Detail

Product Tags

Features
Function Measurement of high voltage AC current, low voltage AC current, on-line monitoring AC current.
Power Supply DC6V Alkaline Dry Battery (1.5V AAA X4pcs)
Test Mode Clamp CT
Transmission Mode 433MHz wireless transmission, distance about 100m
Display Mode 4 digital LCD display, backlight function, suitable for dark place.
LCD Dimension 47mm*28.5mm
Meter Dimension Detector: 210mm*246mm*45mm

Receiver: 78mm*165mm*42mm

CT Size Φ128mm
Sampling Rate 2 times/second
Measure Range 0.00A~9999A(50/60Hz Auto Identification)
Resolution 0.01A
Shift 0.00A ~9999A Automatic Shift
Test Accuracy ±2%rdg±5dgt(The wire is located near the center of the bottom of the u-type clamp, 23℃±2℃)
Position Error The measured conductor should be located as close as possible to the

center of the top of the hook type clamp, and not close to the top of the

u-type clamp. The test error on the top of the u-shaped clamp will

increase by about one time or more

Data Storage 99 sets, in storage process “MEM” symbol display, “FULL” symbol flash

indicate storage is full

Line Voltage Below 110kV current test, operate with insulation rods (below 500kV

can be customized, only for GDCR9000B)

Data Hold In general test mode, press HOLD key to hold data, “HOLD” symbol display. press HOLD Key once again to cancel this function
Data Access “MR” symbol display, it can look over all the stored data
Overflow Display Exceed measurement range overflow function: “OL A” symbol display
No signal Indication When the receiver has not received transmit signal, dynamic display “no- -” symbol.
Auto Shut Down About 15 minutes after booting up, the meter will shut down automatically without any operation, to decrease the battery consumption.
Battery Voltage When the battery voltage is lower than 4.8V, the receiver display low battery voltage symbol “    ”(the detector low voltage display “     ” symbol, the receiver low voltage continue display), remind to replace battery.
Meter Weight Detector: About 300g,

Receiver: 280g

Total weight of meter: about 2300g (including insulation rod and battery.)

Working Temperature -10°C~40°C; Below 80%RH
Storage Temperature -10°C~60°C; Below 70%RH
Interference Should avoid 315Mhz,433Mhz Same frequency signal interference
Insulation Rod Dimension 4300mm
Insulation Strength AC 110kV/rms (The telescopic insulation rod is fully opened between the two ends)
Structure Anti-Dripping Type II